SEC 02 // PART RECORD
15-0499-99 3M Adflo Organic Vapour / Acid Gas (OV/AG) Cartridge
Fits these systems
| System | Compatibility status | Evidence |
|---|---|---|
| 3M Speedglas Adflo PAPR | T2 Manufacturer-listed part |
|
Specifications
| Case packs | 15-0499-99X02 (2/case), 15-0499-99X06 (6/case); a 15-0399-99 OV/AG cartridge also exists (X02/X06) |
|---|---|
| Acid gas approval | NIOSH approval for sulfur dioxide, chlorine, hydrogen chloride |
| Mandatory stack | Must ALWAYS be used with the HE filter, pre-filter and spark arrestor — never alone, never combined with the odour pad |
| Runtime impact | Battery runtime drops to ~5.5 h with the OV/AG cartridge fitted |
Notes
Correction captured against the original research: the manual lists TWO OV/AG cartridge part numbers (15-0399-99 and 15-0499-99) and the nuisance odour pad is 35-0799-99 (assembly 35-0699-99), not a 15-0299-99X suffix. Cartridge service life must be pre-determined via a change-out schedule — the filter-loading indicator tells you nothing about gas/vapour life.
Record sources
Evidence — dated sources
- [01] multimedia.3m.com manufacturer manual 2026-07-04